Availability: | |
---|---|
Quantity: | |
YOUWIN have a wide variety of good quality and mechanical bulk meters. Such as Dry Type Remote-reading Industrial Water Meter, YOUWIN’s bulk water meters are designed for use in industrial & agriculture application.
APPLICATION:
Measuring the volume of cold (hot) water passing through the pipeline.
FEATURE:
Dry Type Remote-reading Industrial Water Meter, dry-dial, magnetic drive sensitive action, small pressure loss;
Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service;
Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline;
Selected high quality materials for steady & reliable characteristic;
Remote-reading Industrial Water Meter,Pulse output: Available 100L or 1000L per pulse for optional;
Technical data conform to international standard ISO 4064 CLASS B(R50).
WORKING CONDITION:
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter)
Water pressure: ≤1.0Mpa
Maximum permissible errors
(1) in the lower zone from qmin inclusive up to but excluding qt is ±5%
(2) in the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter)
YOUWIN have a wide variety of good quality and mechanical bulk meters. Such as Dry Type Remote-reading Industrial Water Meter, YOUWIN’s bulk water meters are designed for use in industrial & agriculture application.
APPLICATION:
Measuring the volume of cold (hot) water passing through the pipeline.
FEATURE:
Dry Type Remote-reading Industrial Water Meter, dry-dial, magnetic drive sensitive action, small pressure loss;
Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service;
Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline;
Selected high quality materials for steady & reliable characteristic;
Remote-reading Industrial Water Meter,Pulse output: Available 100L or 1000L per pulse for optional;
Technical data conform to international standard ISO 4064 CLASS B(R50).
WORKING CONDITION:
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter)
Water pressure: ≤1.0Mpa
Maximum permissible errors
(1) in the lower zone from qmin inclusive up to but excluding qt is ±5%
(2) in the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter)
Model | Size (mm) | Class | qs Overload Flow | qp Permanent Flow | qt Transitional Flow | qmin Min. Flow | Min. Reading | Max. Reading |
m3/h | m3 | |||||||
LXLG-50 | 50 | A | 30 | 15 | 4.5 | 1.2 | 0.0002 | 999,999 |
B | 3.0 | 0.45 | ||||||
LXLG-65 | 65 | A | 50 | 25 | 7.5 | 2.0 | 0.0002 | 999,999 |
B | 5 | 0.75 | ||||||
LXLG-80 | 80 | A | 80 | 40 | 12 | 3.2 | 0.002 | 999,999 |
B | 8.0 | 1.2 | ||||||
LXLG-100 | 100 | A | 120 | 60 | 18 | 4.8 | 0.002 | 999,999 |
B | 12 | 1.8 | ||||||
LXLG-125 | 125 | A | 200 | 100 | 30 | 8 | 0.002 | 999,999 |
B | 20 | 3 | ||||||
LXLG-150 | 150 | A | 300 | 150 | 45 | 12 | 0.002 | 999,999 |
B | 30 | 4.5 | ||||||
LXLG-200 | 200 | A | 500 | 250 | 75 | 20 | 0.002 | 999,999 |
B | 50 | 7.5 | ||||||
LXLG-250 | 250 | A | 800 | 400 | 120 | 32 | 0.002 | 999,999 |
B | 80 | 12 | ||||||
LXLG-300 | 300 | A | 1200 | 600 | 180 | 48 | 0.02 | 9,999,999 |
B | 120 | 18 |
DIMENSIONS AND WEIGHTS
Model | Size | L Length | B Width | H Height | Connecting flange | Weight (KGS) | ||
φD Outside diameter | φD1 Bolt circle diameter | Connecting Bolts (n-M) | ||||||
mm | ||||||||
LXLG-50 | 50 | 200 | 242 | 360 | 165 | 125 | 4-M16 | 12 |
LXLG-65 | 65 | 200 | 242 | 360 | 185 | 145 | 4-M16 | 13 |
LXLG-80 | 80 | 225 | 265 | 360 | 200 | 160 | 8-M16 | 15 |
LXLG-100 | 100 | 250 | 270 | 360 | 220 | 180 | 8-M16 | 19 |
LXLG-125 | 125 | 250 | 275 | 360 | 250 | 210 | 8-M16 | 22 |
LXLG-150 | 150 | 300 | 300 | 420 | 285 | 240 | 8-M20 | 28 |
LXLG-200 | 200 | 350 | 352 | 420 | 340 | 295 | 8-M20(1.0MPa) | 42 |
LXLG-250 | 250 | 400 | 430 | 660 | 395 | 350 | 12-M20(1.0MPa) | 80 |
LXLG-300 | 300 | 450 | 490 | 660 | 445 | 400 | 12-M20(1.0MPa) | 115 |
NOTE: The flange dimension conforms to ISO7005-2:1988 standard. Order for products of special requirements is also accepted.
INSTALLATION REQUIREMENT:
1. The meter should be installed in horizontal position with the register face upwards.
2. The pipeline must be flushed before installation.
3. The meter should be constantly full of water during operation.
Model | Size (mm) | Class | qs Overload Flow | qp Permanent Flow | qt Transitional Flow | qmin Min. Flow | Min. Reading | Max. Reading |
m3/h | m3 | |||||||
LXLG-50 | 50 | A | 30 | 15 | 4.5 | 1.2 | 0.0002 | 999,999 |
B | 3.0 | 0.45 | ||||||
LXLG-65 | 65 | A | 50 | 25 | 7.5 | 2.0 | 0.0002 | 999,999 |
B | 5 | 0.75 | ||||||
LXLG-80 | 80 | A | 80 | 40 | 12 | 3.2 | 0.002 | 999,999 |
B | 8.0 | 1.2 | ||||||
LXLG-100 | 100 | A | 120 | 60 | 18 | 4.8 | 0.002 | 999,999 |
B | 12 | 1.8 | ||||||
LXLG-125 | 125 | A | 200 | 100 | 30 | 8 | 0.002 | 999,999 |
B | 20 | 3 | ||||||
LXLG-150 | 150 | A | 300 | 150 | 45 | 12 | 0.002 | 999,999 |
B | 30 | 4.5 | ||||||
LXLG-200 | 200 | A | 500 | 250 | 75 | 20 | 0.002 | 999,999 |
B | 50 | 7.5 | ||||||
LXLG-250 | 250 | A | 800 | 400 | 120 | 32 | 0.002 | 999,999 |
B | 80 | 12 | ||||||
LXLG-300 | 300 | A | 1200 | 600 | 180 | 48 | 0.02 | 9,999,999 |
B | 120 | 18 |
DIMENSIONS AND WEIGHTS
Model | Size | L Length | B Width | H Height | Connecting flange | Weight (KGS) | ||
φD Outside diameter | φD1 Bolt circle diameter | Connecting Bolts (n-M) | ||||||
mm | ||||||||
LXLG-50 | 50 | 200 | 242 | 360 | 165 | 125 | 4-M16 | 12 |
LXLG-65 | 65 | 200 | 242 | 360 | 185 | 145 | 4-M16 | 13 |
LXLG-80 | 80 | 225 | 265 | 360 | 200 | 160 | 8-M16 | 15 |
LXLG-100 | 100 | 250 | 270 | 360 | 220 | 180 | 8-M16 | 19 |
LXLG-125 | 125 | 250 | 275 | 360 | 250 | 210 | 8-M16 | 22 |
LXLG-150 | 150 | 300 | 300 | 420 | 285 | 240 | 8-M20 | 28 |
LXLG-200 | 200 | 350 | 352 | 420 | 340 | 295 | 8-M20(1.0MPa) | 42 |
LXLG-250 | 250 | 400 | 430 | 660 | 395 | 350 | 12-M20(1.0MPa) | 80 |
LXLG-300 | 300 | 450 | 490 | 660 | 445 | 400 | 12-M20(1.0MPa) | 115 |
NOTE: The flange dimension conforms to ISO7005-2:1988 standard. Order for products of special requirements is also accepted.
INSTALLATION REQUIREMENT:
1. The meter should be installed in horizontal position with the register face upwards.
2. The pipeline must be flushed before installation.
3. The meter should be constantly full of water during operation.