Availability: | |
---|---|
Quantity: | |
APPLICATION:
This turbine type of is Removable Element Woltmann Type Water Meter with magnetic transmission for industrial and irrigation application in sizes 50mm to 300mm and used to measure the volume of cold(hot) water which passing through the pipeline.
FEATURES:
Removable Element Woltmann Type Water Meter,turbine principle, lower transmission resistance;
Magnetic drive, dry-dial, vacuum sealed register, frost resistant, keeps clean reading for long time;
The body is made of cast iron or ductile cast iron coated with epoxy varnish treatment;
The interchangeable, removable measuring mechanism can be easy removed from the body for checking, maintaining and replacing, and the body don’t need to be dismantled from the pipe;
Suitable for any position installation;
The Plastic-Can super dry register with stainless steel flange cover;
Pulse output: Available 100L or 1000L per pulse for optional;
Large size flange type water meter, application in over 50 countries.
CONSTRUCTION:
The Removable Element Woltmann Type Water Meter is mainly consists of a cast iron body, a measuring bulk mechanism, a register unit, a steel flanged cover, and a steel cover with lid. The flange cover secures the internal parts.
COMPLIANCE WITH STANDARD:
Technical data conforms to ISO 4064:2015 Standard for horizontal installation.
WORKING CONDITIONS:
Working temperature Class: T30 or T50 for cold water meter
Working Pressure Class: MAP10
Pressure Loss Class:: P25
Upstream Disturbance Class: U10
Downstream Disturbance Class: D5
ACCESSORIES:
Every water meter will complete with 2pcs flanged rubber gaskets.
MAXIMUM PERMISSIBLE ERROR:
In the lower zone from Q1 inclusive up to but excluding Q2 is: Cold potable water meter ± 5%
In the upper zone from Q2 inclusive up to and including Q4 is: Cold potable water meter ± 2%
INSTALLATION REQUIREMENTS:
Step-1: The meter should be installed in Horizontal position with the direction of the flow as indicated by the arrow cast in the meter body with the register face upwards.
Step-2: Pipeline must be flushed before installation.
Step-3: The meter should be constantly full of water during operation.
APPLICATION:
This turbine type of is Removable Element Woltmann Type Water Meter with magnetic transmission for industrial and irrigation application in sizes 50mm to 300mm and used to measure the volume of cold(hot) water which passing through the pipeline.
FEATURES:
Removable Element Woltmann Type Water Meter,turbine principle, lower transmission resistance;
Magnetic drive, dry-dial, vacuum sealed register, frost resistant, keeps clean reading for long time;
The body is made of cast iron or ductile cast iron coated with epoxy varnish treatment;
The interchangeable, removable measuring mechanism can be easy removed from the body for checking, maintaining and replacing, and the body don’t need to be dismantled from the pipe;
Suitable for any position installation;
The Plastic-Can super dry register with stainless steel flange cover;
Pulse output: Available 100L or 1000L per pulse for optional;
Large size flange type water meter, application in over 50 countries.
CONSTRUCTION:
The Removable Element Woltmann Type Water Meter is mainly consists of a cast iron body, a measuring bulk mechanism, a register unit, a steel flanged cover, and a steel cover with lid. The flange cover secures the internal parts.
COMPLIANCE WITH STANDARD:
Technical data conforms to ISO 4064:2015 Standard for horizontal installation.
WORKING CONDITIONS:
Working temperature Class: T30 or T50 for cold water meter
Working Pressure Class: MAP10
Pressure Loss Class:: P25
Upstream Disturbance Class: U10
Downstream Disturbance Class: D5
ACCESSORIES:
Every water meter will complete with 2pcs flanged rubber gaskets.
MAXIMUM PERMISSIBLE ERROR:
In the lower zone from Q1 inclusive up to but excluding Q2 is: Cold potable water meter ± 5%
In the upper zone from Q2 inclusive up to and including Q4 is: Cold potable water meter ± 2%
INSTALLATION REQUIREMENTS:
Step-1: The meter should be installed in Horizontal position with the direction of the flow as indicated by the arrow cast in the meter body with the register face upwards.
Step-2: Pipeline must be flushed before installation.
Step-3: The meter should be constantly full of water during operation.
DIMENSION PICTURE:
Model No. | Size (inch) | R=Q3/Q1 | Q4 Maximum Flow Rate | Q3 Permanent Flow Rate | Q2 Transitional Flow Rate | Q1 Minimum Flow Rate | Min. Reading | Max. Reading |
m3 | ||||||||
WP-SDG-50 | 2” | 50 | 50 | 40 | 1.28 | 0.80 | 0.005 | 999999 |
80 | 0.80 | 0.50 | 0.001 | |||||
WP-SDG-65 | 2-1/2” | 50 | 50 | 40 | 1.28 | 0.80 | 0.005 | |
80 | 78.70 | 63 | 1.28 | 0.80 | 0.001 | |||
WP-SDG-80 | 3” | 50 | 78.70 | 63 | 2.0 | 1.25 | 0.005 | |
80 | 1.25 | 0.80 | 0.001 | |||||
WP-SDG-100 | 4” | 50 | 125 | 100 | 3.2 | 2.0 | 0.005 | |
80 | 2.0 | 1.25 | 0.001 | |||||
WP-SDG-125 | 5” | 50 | 200 | 160 | 5.0 | 3.2 | 0.005 | |
80 | 3.2 | 2.0 | 0.001 | |||||
WP-SDG-150 | 6” | 50 | 312.5 | 250 | 8.0 | 5.0 | 0.05 | 999999 |
80 | 5.0 | 3.2 | 0.01 | |||||
WP-SDG-200 | 8” | 50 | 500 | 400 | 12.5 | 8.00 | 0.05 | |
80 | 8.0 | 5.0 | 0.01 | |||||
WP-SDG-250 | 10” | 50 | 737 | 630 | 20.0 | 12.5 | 0.5 | |
80 | 12.5 | 8.0 | 0.1 | |||||
WP-SDG-300 | 12” | 50 | 1250 | 1000 | 32.0 | 20.0 | 0.5 | 9999999 |
80 | 20.0 | 12.5 | 0.1 |
Model No. | Size | L Length | W Width | H Height | Flange | Weight KG | |||
mm | Outside Diameter D(mm) | Circle diameter D1(mm) | Connecting bolt quantity NxM | ||||||
WP-SDG-50 | 50 | 200 | 232 | 380 | 165 | 125 | 4 x M16 | 12 | |
WP-SDG-65 | 65 | 200 | 242 | 380 | 185 | 145 | 13 | ||
WP-SDG-80 | 80 | 225 | 252 | 380 | 200 | 160 | 8 x M16 | 18 | |
WP-SDG-100 | 100 | 250 | 262 | 380 | 220 | 180 | 20 | ||
WP-SDG-125 | 125 | 250 | 275 | 420 | 250 | 210 | 25 | ||
WP-SDG-150 | 150 | 300 | 325 | 420 | 285 | 240 | 8 x M20 | 31 | |
WP-SDG-200 | 200 | 350 | 352 | 660 | 340 | 295 | 45 | ||
WP-SDG-250 | 250 | 450 | 470 | 660 | 395 | 350 | 12 x M20 | 85 | |
WP-SDG-300 | 300 | 500 | 492 | 660 | 445 | 400 | 105 |
FLOW ERROR CURVE:
PRESSURE LOSS CURVE
DIMENSION PICTURE:
Model No. | Size (inch) | R=Q3/Q1 | Q4 Maximum Flow Rate | Q3 Permanent Flow Rate | Q2 Transitional Flow Rate | Q1 Minimum Flow Rate | Min. Reading | Max. Reading |
m3 | ||||||||
WP-SDG-50 | 2” | 50 | 50 | 40 | 1.28 | 0.80 | 0.005 | 999999 |
80 | 0.80 | 0.50 | 0.001 | |||||
WP-SDG-65 | 2-1/2” | 50 | 50 | 40 | 1.28 | 0.80 | 0.005 | |
80 | 78.70 | 63 | 1.28 | 0.80 | 0.001 | |||
WP-SDG-80 | 3” | 50 | 78.70 | 63 | 2.0 | 1.25 | 0.005 | |
80 | 1.25 | 0.80 | 0.001 | |||||
WP-SDG-100 | 4” | 50 | 125 | 100 | 3.2 | 2.0 | 0.005 | |
80 | 2.0 | 1.25 | 0.001 | |||||
WP-SDG-125 | 5” | 50 | 200 | 160 | 5.0 | 3.2 | 0.005 | |
80 | 3.2 | 2.0 | 0.001 | |||||
WP-SDG-150 | 6” | 50 | 312.5 | 250 | 8.0 | 5.0 | 0.05 | 999999 |
80 | 5.0 | 3.2 | 0.01 | |||||
WP-SDG-200 | 8” | 50 | 500 | 400 | 12.5 | 8.00 | 0.05 | |
80 | 8.0 | 5.0 | 0.01 | |||||
WP-SDG-250 | 10” | 50 | 737 | 630 | 20.0 | 12.5 | 0.5 | |
80 | 12.5 | 8.0 | 0.1 | |||||
WP-SDG-300 | 12” | 50 | 1250 | 1000 | 32.0 | 20.0 | 0.5 | 9999999 |
80 | 20.0 | 12.5 | 0.1 |
Model No. | Size | L Length | W Width | H Height | Flange | Weight KG | |||
mm | Outside Diameter D(mm) | Circle diameter D1(mm) | Connecting bolt quantity NxM | ||||||
WP-SDG-50 | 50 | 200 | 232 | 380 | 165 | 125 | 4 x M16 | 12 | |
WP-SDG-65 | 65 | 200 | 242 | 380 | 185 | 145 | 13 | ||
WP-SDG-80 | 80 | 225 | 252 | 380 | 200 | 160 | 8 x M16 | 18 | |
WP-SDG-100 | 100 | 250 | 262 | 380 | 220 | 180 | 20 | ||
WP-SDG-125 | 125 | 250 | 275 | 420 | 250 | 210 | 25 | ||
WP-SDG-150 | 150 | 300 | 325 | 420 | 285 | 240 | 8 x M20 | 31 | |
WP-SDG-200 | 200 | 350 | 352 | 660 | 340 | 295 | 45 | ||
WP-SDG-250 | 250 | 450 | 470 | 660 | 395 | 350 | 12 x M20 | 85 | |
WP-SDG-300 | 300 | 500 | 492 | 660 | 445 | 400 | 105 |
FLOW ERROR CURVE:
PRESSURE LOSS CURVE
WP-SDG-50-300 Part List of Removable Element Woltmann Dry Type Water Meter | |||
Code | Description | Material | QTY |
1 | Screw For Sealing | Stainless Steel | 1 |
2 | Cover With Lid | Assembly | 1 |
3 | Sealed Register | Assembly | 1 |
4 | Screw M4×20 | Stainless Steel | 2 |
5 | Gasket | Brass | 2 |
6 | Adjusting Nut | Brass | 1 |
7 | Flange Cover | Cast Iron | 1 |
8 | O-ring | Silicon Rubber | 1 |
9 | Bush | Brass | 1 |
10 | Gasket | Synthetic Rubber | 1 |
11 | Adjusting Lever | Brass | 1 |
12 | Connecting Lever | POM OR MPPO | 1 |
13 | Adjusting Plate | POM OR MPPO | 1 |
14 | Support | ABS OR MPPO | 1 |
15 | Turbine Component | Assembly | 1 |
16 | Rectifier | ABS OR MPPO | 1 |
17 | Screw | Brass | 1 |
18 | O-ring | Synthetic Rubber | 1 |
19 | Body | Cast Iron | 1 |
20 | Screw For Sealing | Stainless Steel | 1 |
21 | Screw For Sealing | Stainless Steel | 3 |
22 | Support | ABS | 1 |
23 | Screw M4×20 | Stainless Steel | 2 |
24 | Gasket | Stainless Steel | 4 |
25 | Upper Bearing Plate | Brass | 1 |
26 | Upper Bearing | Nylon With Graphite | 1 |
27 | Magnet Component | Component | 1 |
28 | Transmission Shaft | Stainless Steel | 1 |
29 | Sheath | Nylon | 2 |
30 | Bevel Gear | POM | 1 |
31 | Bevel Gear | Nylon | 1 |
32 | Gasket | Stainless Steel | 4 |
33 | ScrewM5X12 | Stainless Steel | 4 |
34 | Nut | Brass | 1 |
35 | Gasket | Brass | 1 |
36 | Turbine Shaft Hold | Brass | 1 |
37 | Turbine Shaft | Tungsten Steel | 1 |
WP-SDG-50-300 Part List of Removable Element Woltmann Dry Type Water Meter | |||
Code | Description | Material | QTY |
1 | Screw For Sealing | Stainless Steel | 1 |
2 | Cover With Lid | Assembly | 1 |
3 | Sealed Register | Assembly | 1 |
4 | Screw M4×20 | Stainless Steel | 2 |
5 | Gasket | Brass | 2 |
6 | Adjusting Nut | Brass | 1 |
7 | Flange Cover | Cast Iron | 1 |
8 | O-ring | Silicon Rubber | 1 |
9 | Bush | Brass | 1 |
10 | Gasket | Synthetic Rubber | 1 |
11 | Adjusting Lever | Brass | 1 |
12 | Connecting Lever | POM OR MPPO | 1 |
13 | Adjusting Plate | POM OR MPPO | 1 |
14 | Support | ABS OR MPPO | 1 |
15 | Turbine Component | Assembly | 1 |
16 | Rectifier | ABS OR MPPO | 1 |
17 | Screw | Brass | 1 |
18 | O-ring | Synthetic Rubber | 1 |
19 | Body | Cast Iron | 1 |
20 | Screw For Sealing | Stainless Steel | 1 |
21 | Screw For Sealing | Stainless Steel | 3 |
22 | Support | ABS | 1 |
23 | Screw M4×20 | Stainless Steel | 2 |
24 | Gasket | Stainless Steel | 4 |
25 | Upper Bearing Plate | Brass | 1 |
26 | Upper Bearing | Nylon With Graphite | 1 |
27 | Magnet Component | Component | 1 |
28 | Transmission Shaft | Stainless Steel | 1 |
29 | Sheath | Nylon | 2 |
30 | Bevel Gear | POM | 1 |
31 | Bevel Gear | Nylon | 1 |
32 | Gasket | Stainless Steel | 4 |
33 | ScrewM5X12 | Stainless Steel | 4 |
34 | Nut | Brass | 1 |
35 | Gasket | Brass | 1 |
36 | Turbine Shaft Hold | Brass | 1 |
37 | Turbine Shaft | Tungsten Steel | 1 |