Availability: | |
---|---|
Quantity: | |
APPLICATION:
This flange type is turbine water meter with magnetic transmission for industrial and irrigation application in sizes 50mm to 300mm and used to measure the volume of cold water which passing through the pipeline.
FEATURE:
Dry Type Industrial Flange Water Meter,turbine principle, cast iron-can tight with flange cover;
Magnetic drive, dry-dial, vacuum sealed register, frost resistant, keeps clean reading for long time;
The body can made by Stainless Steel ,Cast iron, Nylon plastic for optional.
The interchangeable, removable measuring mechanism can be easy removed from the body for checking, maintaining and replacing, and the body don’t need to be dismantled from the pipe;
Selected high quality materials for steady & reliable performance;
Remote-reading flanged water meter, Pulse output: Available 100L or 1000L per pulse for optional;
Approvals in over 20 countries.
CONSTRUCTION:
The Dry Type Industrial Flange Water Meter is mainly consists that a cast iron body, a bulk measuring mechanism, a register unit, a flanged cover, and a cover with lid. The flange cover secures the internal parts.
COMPLIANCE WITH STANDARD
Technical data conforms to ISO 4064:2015 Standard for horizontal installation.
WORKING CONDITIONS
Working temperature Class: T30 or T50 for cold water meter.
Working Pressure Class: MAP10
Pressure Loss Class: P25
Upstream Disturbance Class: U5
Downstream Disturbance Class: D3
ACCESSORIES
Every water meter will complete with 2pcs flanged gaskets.
MAXIMUM PERMISSIBLE ERROR
In the lower zone from Q1 inclusive up to but excluding Q2 is: Cold potable and hot water meter ± 5%
In the upper zone from Q2 inclusive up to and including Q4 is: Cold potable water meter ± 2%, hot water meter ± 3%.
INSTALLATION REQUIREMENTS
Step-1: The meter should be installed in Horizontal position with the direction of the flow as indicated by the arrow cast in the meter body with the register face upwards.
Step-2: Pipeline must be flushed before installation.
Step-3: The meter should be constantly full of water during operation.
APPLICATION:
This flange type is turbine water meter with magnetic transmission for industrial and irrigation application in sizes 50mm to 300mm and used to measure the volume of cold water which passing through the pipeline.
FEATURE:
Dry Type Industrial Flange Water Meter,turbine principle, cast iron-can tight with flange cover;
Magnetic drive, dry-dial, vacuum sealed register, frost resistant, keeps clean reading for long time;
The body can made by Stainless Steel ,Cast iron, Nylon plastic for optional.
The interchangeable, removable measuring mechanism can be easy removed from the body for checking, maintaining and replacing, and the body don’t need to be dismantled from the pipe;
Selected high quality materials for steady & reliable performance;
Remote-reading flanged water meter, Pulse output: Available 100L or 1000L per pulse for optional;
Approvals in over 20 countries.
CONSTRUCTION:
The Dry Type Industrial Flange Water Meter is mainly consists that a cast iron body, a bulk measuring mechanism, a register unit, a flanged cover, and a cover with lid. The flange cover secures the internal parts.
COMPLIANCE WITH STANDARD
Technical data conforms to ISO 4064:2015 Standard for horizontal installation.
WORKING CONDITIONS
Working temperature Class: T30 or T50 for cold water meter.
Working Pressure Class: MAP10
Pressure Loss Class: P25
Upstream Disturbance Class: U5
Downstream Disturbance Class: D3
ACCESSORIES
Every water meter will complete with 2pcs flanged gaskets.
MAXIMUM PERMISSIBLE ERROR
In the lower zone from Q1 inclusive up to but excluding Q2 is: Cold potable and hot water meter ± 5%
In the upper zone from Q2 inclusive up to and including Q4 is: Cold potable water meter ± 2%, hot water meter ± 3%.
INSTALLATION REQUIREMENTS
Step-1: The meter should be installed in Horizontal position with the direction of the flow as indicated by the arrow cast in the meter body with the register face upwards.
Step-2: Pipeline must be flushed before installation.
Step-3: The meter should be constantly full of water during operation.
DIMENSION PICTURE
Model No. | Size (inch) | R=Q3/Q1 | Q4 Maximum Flow Rate | Q3 Permanent Flow Rate | Q2 Transitional Flow Rate | Q1 Minimum Flow Rate | Min. Reading | Max. Reading |
m3 | ||||||||
WMG-50A | 2” | 50 | 50 | 40 | 1.28 | 0.80 | 0.005 | 999999 |
80 | 0.80 | 0.50 | 0.001 | |||||
WMG-65A | 2-1/2” | 50 | 50 | 40 | 1.28 | 0.80 | 0.005 | |
80 | 78.70 | 63 | 1.28 | 0.80 | 0.001 | |||
WMG-80A | 3” | 50 | 78.70 | 63 | 2.0 | 1.25 | 0.005 | |
80 | 1.25 | 0.80 | 0.001 | |||||
WMG-100A | 4” | 50 | 125 | 100 | 3.2 | 2.0 | 0.005 | |
80 | 2.0 | 1.25 | 0.001 | |||||
WMG-125A | 5” | 50 | 200 | 160 | 5.0 | 3.2 | 0.005 | |
80 | 3.2 | 2.0 | 0.001 | |||||
WMG-150A | 6” | 50 | 312.5 | 250 | 8.0 | 5.0 | 0.05 | 999999 |
80 | 5.0 | 3.2 | 0.01 | |||||
WMG-200A | 8” | 50 | 500 | 400 | 12.5 | 8.00 | 0.05 | |
80 | 8.0 | 5.0 | 0.01 |
Model No. | Size | L Length | W Width | H Height | Flange | Weight KG | |||
mm | Outside Diameter D(mm) | Circle diameter D1(mm) | Connecting bolt quantity NxM | ||||||
WMG-50A | 50 | 200 | 172 | 247 | 165 | 125 |
4 x M16 | 12 | |
WMG-65A | 65 | 200 | 185 | 260 | 185 | 145 | 13 | ||
WMG-80A | 80 | 225 | 200 | 265 | 200 | 160 | 8 x M16 | 15 | |
WMG-100A | 100 | 250 | 225 | 272 | 220 | 180 | 19 | ||
WMG-125A | 125 | 250 | 250 | 295 | 250 | 210 | 23 | ||
WMG-150A | 150 | 300 | 285 | 302 | 285 | 240 | 8 x M20 | 30 | |
WMG-200A | 200 | 350 | 340 | 359 | 340 | 295 | 42 |
FLOW ERROR CURVE
HEAD LOSS CURVE
DIMENSION PICTURE
Model No. | Size (inch) | R=Q3/Q1 | Q4 Maximum Flow Rate | Q3 Permanent Flow Rate | Q2 Transitional Flow Rate | Q1 Minimum Flow Rate | Min. Reading | Max. Reading |
m3 | ||||||||
WMG-50A | 2” | 50 | 50 | 40 | 1.28 | 0.80 | 0.005 | 999999 |
80 | 0.80 | 0.50 | 0.001 | |||||
WMG-65A | 2-1/2” | 50 | 50 | 40 | 1.28 | 0.80 | 0.005 | |
80 | 78.70 | 63 | 1.28 | 0.80 | 0.001 | |||
WMG-80A | 3” | 50 | 78.70 | 63 | 2.0 | 1.25 | 0.005 | |
80 | 1.25 | 0.80 | 0.001 | |||||
WMG-100A | 4” | 50 | 125 | 100 | 3.2 | 2.0 | 0.005 | |
80 | 2.0 | 1.25 | 0.001 | |||||
WMG-125A | 5” | 50 | 200 | 160 | 5.0 | 3.2 | 0.005 | |
80 | 3.2 | 2.0 | 0.001 | |||||
WMG-150A | 6” | 50 | 312.5 | 250 | 8.0 | 5.0 | 0.05 | 999999 |
80 | 5.0 | 3.2 | 0.01 | |||||
WMG-200A | 8” | 50 | 500 | 400 | 12.5 | 8.00 | 0.05 | |
80 | 8.0 | 5.0 | 0.01 |
Model No. | Size | L Length | W Width | H Height | Flange | Weight KG | |||
mm | Outside Diameter D(mm) | Circle diameter D1(mm) | Connecting bolt quantity NxM | ||||||
WMG-50A | 50 | 200 | 172 | 247 | 165 | 125 |
4 x M16 | 12 | |
WMG-65A | 65 | 200 | 185 | 260 | 185 | 145 | 13 | ||
WMG-80A | 80 | 225 | 200 | 265 | 200 | 160 | 8 x M16 | 15 | |
WMG-100A | 100 | 250 | 225 | 272 | 220 | 180 | 19 | ||
WMG-125A | 125 | 250 | 250 | 295 | 250 | 210 | 23 | ||
WMG-150A | 150 | 300 | 285 | 302 | 285 | 240 | 8 x M20 | 30 | |
WMG-200A | 200 | 350 | 340 | 359 | 340 | 295 | 42 |
FLOW ERROR CURVE
HEAD LOSS CURVE